Dryer not heating?
A dryer that tumbles but blows cold air is the most common dryer call we take. On electric dryers it's the heating element, thermal fuse, a thermostat or a half-tripped 240V breaker; on gas dryers it's the igniter, flame sensor or gas valve coils. We carry all of them.
- Most likely cause
- Heating element or thermal fuse (electric); igniter or gas valve coils (gas)
- Typical repair time
- One visit, 30–60 minutes
- Service call
- $89 diagnostic, credited to the repair
Why it's happening, in order of likelihood
Our technicians test in roughly this order. The numbers reflect how often each cause turns out to be the fault on Houston service calls.
- 1
Half-tripped 240V breaker (electric)
The motor runs on 120V; the element needs both legs. One tripped leg gives a running, cold dryer. Switch the double breaker fully off and on.
- 2
Heating element (electric)
The coil breaks and the circuit opens. Common after 6–10 years, sooner with a restricted vent.
- 3
Thermal fuse
A one-time safety fuse that blows when the dryer overheats, almost always because the vent is restricted. Replace the fuse and fix the airflow or it blows again.
- 4
Cycling or high-limit thermostat
A thermostat stuck open keeps the element off.
- 5
Igniter (gas)
The igniter glows but has weakened and no longer proves the flame; the valve never opens. The most common gas dryer repair.
- 6
Gas valve coils (gas)
The dryer heats for a few minutes then goes cold for the rest of the cycle. Classic coil failure.
- 7
Flame sensor (gas)
The igniter never glows at all.
- 8
Control board or timer
A failed heat relay. Less common.
Check these before you call
Safe, no-tools checks. If none of them solves it, the next step is a technician.
- Electric: cycle the 240V double breaker fully off and back on.
- Gas: confirm the gas supply valve behind the dryer is open and other gas appliances work.
- Check the vent: a restricted vent causes most thermal fuse failures. Clean the lint screen and look at the transition hose.
- Note whether it heats briefly then goes cold (coils) or never heats (igniter, element, fuse).
Parts we typically replace
- Heating element
- Thermal fuse
- Cycling thermostat
- High-limit thermostat
- Igniter
- Gas valve coils
- Flame sensor
- Control board
Brand-specific notes
- WhirlpoolWhirlpool, Maytag and Kenmore 110-series dryers: thermal fuse plus element on electric; coils on gas. L2 on a Maytag means a missing 240V leg.
- SamsungSamsung HE/HC codes: element or thermistor on electric models.
- LGLG electric dryers often fail the element; gas models the igniter or coils.
- GE AppliancesGE dryers fail the element and the thermal fuse; GE gas dryers the igniter.
Repair or replace?
Nearly always a repair. These parts are inexpensive and dryers last 15+ years.
What happens on the visit
Describe the symptom
Tell us the brand, model and what it's doing. A photo of the model tag helps.
We diagnose, you approve
$89 diagnostic, credited to the repair. Flat-rate quote before any work.
Fixed, usually that visit
Common parts are on the truck. 1-year parts, 90-day labor warranty on the repair.
Questions about this problem
Why did my dryer stop heating right after the vent clogged?
Why does my gas dryer heat for five minutes then go cold?
Is a dryer that doesn't heat a fire risk?
Related dryer problems
Dryer Not Turning On
A blown thermal fuse or a failed door switch.
See causes & fixesDryer Takes Too Long
A restricted dryer vent.
See causes & fixesDryer Making Noise
Worn drum rollers, idler pulley or drum glides.
See causes & fixesDryer Drum Not Turning
A broken drive belt.
See causes & fixesDryer Overheating or Burning Smell
Restricted airflow with lint near the heater, or a failed cycling thermostat.
See causes & fixesDryer Stops Mid-Cycle
Overheating from a restricted vent, a worn door switch or a failing motor.
See causes & fixes