Current models show F# E# pairs plus AF, L2 and PF; older electronic models show F01–F31 style codes. Lights-only models store codes that are read in the diagnostic mode printed on the tech sheet inside the console.
Whirlpool Electric & gas dryers: error codes & what they mean
18 codes explained for WED4815 – WED5050 / WGD4815 – WGD5050, WED6120 / WED7120 / WED8127 / WED9620, WED560L / WHD560C models, with the part or problem behind each one. Same-day dryer repair across Houston.
Models covered
Find the model number on the rating plate. Washers: under the lid or inside the door frame. Dryers: inside the door. Refrigerators: inside the fresh-food compartment on the wall. Dishwashers: on the door edge. Ranges: on the frame behind the door or the drawer.
- WED4815 – WED5050 / WGD4815 – WGD5050Standard 29-inch electric (WED) and gas (WGD) dryers: WED4815EW, WED4950HW, WED5000DW, WED5050LW, WGD4950HW.
- WED6120 / WED7120 / WED8127 / WED9620Larger and steam models matching the top-load and front-load washers.
- WED560L / WHD560C (compact)24-inch compact and ventless heat-pump dryers.
- Cabrio & Duet dryers (2005–2016)WED6400, WED7300, WED9200, WED94HEX with the F01–F31 code set.
Example model numbers
- WED4815EW
- WED4950HW
- WED5000DW
- WED5050LW
- WGD4950HW
- WED7120HW
- WED9620HC
- WED94HEXW
Whirlpool dryers (also sold as Maytag, Amana, Roper, Admiral and Kenmore 110) are the simplest machines we repair. Two codes cover most calls: AF (restricted airflow) and L2 (one leg of 240V missing). A dryer that runs cold with no code at all usually has a blown thermal fuse or a failed element on electric models, or a weak igniter or coils on gas.
The thermal fuse on these dryers is a one-time safety: it blows when the vent restricts airflow and the dryer overheats. Replacing it without clearing the vent means it blows again.
Whirlpool dryer error codes
Filter by code or symptom. Meanings are the documented common ones for these platforms; the tech sheet inside your appliance is authoritative for your exact model.
| Code | What it means | What usually fixes it |
|---|---|---|
AF / F4 E3 | Restricted airflow | Lint screen, transition hose, vent, exterior flap. |
L2 | Low or no line voltage | One lost 240V leg: breaker, cord, outlet. |
PF | Power failure during cycle | Restart; informational. |
F1 E1 | Main control board failure | Control board. |
F2 E1 | Stuck key | Keypad. |
F2 E5 | Configuration / board mismatch | Correct board or programming. |
F3 E1 | Exhaust thermistor open or shorted | Exhaust thermistor. |
F3 E2 | Moisture sensor fault | Clean the sensor bars; sensor if cleaning fails. |
F3 E3 | Inlet thermistor open or shorted | Inlet thermistor near the heater. |
F4 E1 | Heater circuit fault (relay stuck or element shorted) | Heater relay or element; treated as urgent. |
F4 E4 | Heating element open (electric) | Element, thermal fuse or thermostat; vent checked for the root cause. |
F5 E1 | Door switch fault | Door switch or strike. |
F6 E1 / F6 E2 | Communication error | Harness or boards. |
No match in the main table; check the tables below or text us the code.
Older two-digit codes
| Code | What it means | What usually fixes it |
|---|---|---|
F01 | Primary control failure | Control board. |
F02 | Keypad / user interface failure | UI or stuck key. |
F22 / F23 | Exhaust thermistor open / shorted | Thermistor. |
F24 / F25 | Inlet thermistor open / shorted | Inlet thermistor. |
F28 / F29 | Moisture sensor open / shorted | Moisture sensor or wiring. |
Common failures on these models
- Blown thermal fuses and heating elements from restricted vents (AF)
- One lost 240V leg reported as L2 or no heat
- Thermistor faults after overheating (F3 E1 / F3 E3)
- Moisture sensor film (F3 E2) causing wrong auto-dry
- Idler pulley, rollers and belt wear (noise, drum not turning)
- Door switch failures (F5 E1)
Before you call
- Write down or photograph the exact code and which lights are lit before you reset anything; a reset can erase it.
- Reset once: switch the breaker off for 60 seconds, then back on. A code that returns is real.
- Check the basics the code points to (water valves open, drain hose not kinked, door fully closed, 240V breaker not half-tripped) using the table above.
- Text the code and a photo of the model tag to (713) 548-7587 so we arrive with the part.