Codes appear on the display. Flow Sense (d80, d90, d95) is the dryer measuring airflow restriction and is a vent problem, not a dryer failure. nP and PS are power-supply codes from the 240V connection.
Models covered
Find the model number on the rating plate. Refrigerators: inside on the left wall above the top shelf. Washers: inside the door rim or on the back. Dryers: inside the door. Dishwashers: left edge of the door. Ranges: behind the storage drawer or on the frame.
- DLEX3700 – DLEX4500Electric dryers with Flow Sense and TurboSteam (DLEX3700W, DLEX3900W, DLEX4000W, DLEX4200W, DLEX4500B).
- DLGX3701 – DLGX4501Gas versions of the same platform.
- DLE7xxx / DLG7xxx / DLE3400Mid-range electric and gas dryers (DLE7300WE, DLG7301WE, DLE3400W).
- DLHC / WKEX (WashTower dryer)Ventless heat-pump dryers and the dryer half of WashTower.
- DLE2xxx / DLG2xxx (older)DLE2516W, DLE2140W and relatives.
Example model numbers
- DLEX3700W
- DLEX3900W
- DLEX4000W
- DLEX4200W
- DLGX3701W
- DLE7300WE
- DLHC1455W
LG dryers are honest about airflow: d80 means your vent is roughly 80% blocked, and the dryer will take forever until the duct is cleared. In two-story Houston homes with long vent runs this is the single most common LG dryer code we see, and clearing the vent at the dryer and the wall often fixes a 'broken' dryer.
nP and PS are the other frequent ones: the dryer tumbles but won't heat because one leg of 240V is missing (nP) or the cord was wired wrong at the terminal block (PS). Check the double breaker first.
LG dryer error codes
Filter by code or symptom. Meanings are the documented common ones for these platforms; the tech sheet inside your appliance is authoritative for your exact model.
| Code | What it means | What usually fixes it |
|---|---|---|
d75 / d80 / d90 / d95 | Exhaust duct restricted 75–95% (Flow Sense) | Clear the lint screen, transition hose and vent; on gas dryers d80 can also mean no gas supply. |
nP | No current at the heater | One leg of 240V missing: breaker, cord or outlet. An electrician if the dryer side checks out. |
PS | Power cord wired incorrectly or improper voltage | Terminal block wiring (white/red reversed) or outlet. |
dE | Door not fully closed | Door switch, strike, or lint filter not seated. |
E13 | Drain hose kinked/clogged or sump frozen (condensing hybrid dryers) | Straighten or clear the drain hose. |
F0 / Insert Filter | Lint filter not seated | Reinsert the filter. |
HS | Humidity sensor fault | Clean the sensor bars; replace the sensor if it persists. |
PF | Power failure | Factory reset: unplug, hold Start/Pause 5 seconds, restore power. |
tE1 / tE3 | Thermistor fault | Temperature sensor or harness. |
tE2 | Thermistor fault in cold conditions or steam cycles | Clear vents of cold-air backflow; sensor if it returns. |
gAS (shown as 9A5) | No gas reaching a gas dryer | Gas valve open? Then igniter, coils or the supply. |
Add | Steam feeder needs water | Fill the steam reservoir with tap water. |
No match in the main table; check the tables below or text us the code.
Messages that aren't faults
Things the display shows that don't mean a part has failed.
| Code | What it means | What usually fixes it |
|---|---|---|
CL | Child lock | Hold Child Lock 3 seconds. |
Clean Filter | Reminder before each load | Clean the lint filter. |
Common failures on these models
- Restricted vents (d80 / d90 / d95) and blown thermal fuses
- Heating element failures on electric models
- Igniter and gas valve coil faults on DLGX gas dryers
- Idler pulley and roller noise
- Moisture sensor film (HS) causing wrong auto-dry times
Before you call
- Write down or photograph the exact code and which lights are lit before you reset anything; a reset can erase it.
- Reset once: switch the breaker off for 60 seconds, then back on. A code that returns is real.
- Check the basics the code points to (water valves open, drain hose not kinked, door fully closed, 240V breaker not half-tripped) using the table above.
- Text the code and a photo of the model tag to (713) 548-7587 so we arrive with the part.