Codes show on the display as a two- or three-character string (tS, HC, dC, 9C1). A lit vent icon or Clg means the dryer measured restricted airflow and is a maintenance message, not a part failure.
Models covered
Find the model number on the rating plate. Refrigerators: inside the fresh-food section on the left wall. Washers: inside the lid or door frame, or on the rear panel. Dryers: inside the door. Dishwashers: on the edge of the door. Ranges: inside the storage drawer or on the frame behind the door.
- DVE / DVG 45 – 5527-inch electric (DVE) and gas (DVG) dryers: DVE45R6100, DVE45T6000, DVE50R5400, DVG45T6000, DVE55CG7100.
- DV42 / DV45 / DV48 / DV50 (older)DV42H5000, DV45H7000, DV48H7400, DV50K7500 from 2013–2018.
- DV22 / DVE2224-inch compact ventless and vented dryers for townhomes and condos.
Example model numbers
- DVE45R6100W
- DVE45T6000W
- DVE50R5400V
- DVG45T6000W
- DV45H7000EW
- DVE22N6850X
Samsung dryer codes split into heat codes (HC, hE, tS, tE) and everything else. On electric models a heat code is the heating element, the thermal cutoff or a thermistor that overheated because the vent is restricted, and on gas models it is the igniter, flame sensor or valve coils.
Before any dryer code, check the 240-volt double breaker. A dryer that tumbles but shows HC with no heat often has one tripped leg, which the dryer reports as a heating fault or as 9C1.
Samsung dryer error codes
Filter by code or symptom. Meanings are the documented common ones for these platforms; the tech sheet inside your appliance is authoritative for your exact model.
| Code | What it means | What usually fixes it |
|---|---|---|
tS / tE / tC / tE5 | Thermistor fault | Temperature sensor open or shorted; often after a restricted vent overheated it. |
HC / HE | Heating fault (electric) | Heating element, thermal cutoff or thermistor; check the 240V breaker first. |
hE | Heating fault (gas) | Igniter, flame sensor or gas valve coils. |
dC / dE / dO | Door open or door switch fault | Door switch or strike. |
bC / bE | Stuck button | Keypad or UI board. |
9C1 / 9E1 | Voltage out of range | Supply voltage; one lost 240V leg is common. |
FC / FE | Power frequency error | Supply frequency out of range; usually a generator or wiring issue. |
AC / AE | Communication error | Board harness or failed board. |
3C / 3E | Motor fault | Drive motor or its relay; a seized drum roller can trigger it. |
Clg / Cg / Clean filter | Lint filter reminder or vent restriction indicator | Clean the filter; on Vent Sensor models a lit vent icon means restricted airflow. |
No match in the main table; check the tables below or text us the code.
Common failures on these models
- Heating element failures and blown thermal cutoffs from restricted vents
- Idler pulley and drum roller noise
- Door switch faults (dC / dE)
- Gas valve coils dropping out mid-cycle (heats, then goes cold)
- Moisture sensor film causing long auto-dry cycles
Before you call
- Write down or photograph the exact code and which lights are lit before you reset anything; a reset can erase it.
- Reset once: switch the breaker off for 60 seconds, then back on. A code that returns is real.
- Check the basics the code points to (water valves open, drain hose not kinked, door fully closed, 240V breaker not half-tripped) using the table above.
- Text the code and a photo of the model tag to (713) 548-7587 so we arrive with the part.