Current models show F# E# pairs plus AF, L2 and PF; older electronic models show F01–F31 style codes. Lights-only models store codes that are read in the diagnostic mode printed on the tech sheet inside the console.
Models covered
Find the model number on the rating plate. Washers: under the lid. Dryers: inside the door. Refrigerators: inside the fresh-food section.
- NED4655 / NED4755 / NED4600 / NGD4655 / NGD4755Electric (NED) and gas (NGD) dryers (NED4655EW, NED4755EW, NGD4655EW, NGD4755EW).
- Older NDE / ALEMechanical-timer dryers.
Example model numbers
- NED4655EW
- NED4755EW
- NED4600YQ
- NGD4655EW
- NGD4755EW
How codes are displayed
Amana dryers are Whirlpool 29-inch dryers: AF for restricted airflow, L2 for a missing 240V leg, PF for a power interruption. Most no-heat calls show no code and come down to the thermal fuse, element or thermostats on electric models and the igniter or coils on gas.
Amana dryer error codes
Filter by code or symptom. Meanings are the documented common ones for these platforms; the tech sheet inside your appliance is authoritative for your exact model.
| Code | What it means | What usually fixes it |
|---|---|---|
AF / F4 E3 | Restricted airflow | Lint screen, transition hose, vent, exterior flap. |
L2 | Low or no line voltage | One lost 240V leg: breaker, cord, outlet. |
PF | Power failure during cycle | Restart; informational. |
F1 E1 | Main control board failure | Control board. |
F2 E1 | Stuck key | Keypad. |
F2 E5 | Configuration / board mismatch | Correct board or programming. |
F3 E1 | Exhaust thermistor open or shorted | Exhaust thermistor. |
F3 E2 | Moisture sensor fault | Clean the sensor bars; sensor if cleaning fails. |
F3 E3 | Inlet thermistor open or shorted | Inlet thermistor near the heater. |
F4 E1 | Heater circuit fault (relay stuck or element shorted) | Heater relay or element; treated as urgent. |
F4 E4 | Heating element open (electric) | Element, thermal fuse or thermostat; vent checked for the root cause. |
F5 E1 | Door switch fault | Door switch or strike. |
F6 E1 / F6 E2 | Communication error | Harness or boards. |
No match in the main table; check the tables below or text us the code.
Common failures on these models
- Blown thermal fuses and heating elements from restricted vents (AF)
- One lost 240V leg reported as L2 or no heat
- Thermistor faults after overheating (F3 E1 / F3 E3)
- Moisture sensor film (F3 E2) causing wrong auto-dry
- Idler pulley, rollers and belt wear (noise, drum not turning)
- Door switch failures (F5 E1)
Before you call
- Write down or photograph the exact code and which lights are lit before you reset anything; a reset can erase it.
- Reset once: switch the breaker off for 60 seconds, then back on. A code that returns is real.
- Check the basics the code points to (water valves open, drain hose not kinked, door fully closed, 240V breaker not half-tripped) using the table above.
- Text the code and a photo of the model tag to (713) 548-7587 so we arrive with the part.
Amana dryer questions
My Amana dryer is completely dead.
On this platform the thermal fuse is in the motor circuit; when it blows, the dryer is dead. We replace the fuse and clear the vent restriction that caused it.
Do you repair every Amana dryer model?
Yes, out of warranty. Text us the full model number from the rating plate and the code on the display, and we'll bring the right part. If the unit is still under Amana's factory warranty, call the manufacturer first.